SARS-CoV-2 (COVID-19) Nucleocapsid antibody [HL249], Unconjugated, Rabbit, Monoclonal

Catalog Number: GTX635678
Article Name: SARS-CoV-2 (COVID-19) Nucleocapsid antibody [HL249], Unconjugated, Rabbit, Monoclonal
Biozol Catalog Number: GTX635678
Supplier Catalog Number: GTX635678
Alternative Catalog Number: GTX635678-100,GTX635678-25
Manufacturer: GeneTex
Host: Rabbit
Category: Antikörper
Application: ELISA, ICC, IHC-P, WB
Species Reactivity: Virus
Immunogen: Full length SARS-CoV-2 (COVID-19) nucleocapsid Recombinant protein. (SARS-CoV-2 (strain Wuhan-Hu-1))
Conjugation: Unconjugated
Alternative Names: 2019-nCoV NP, 2019-nCoV Nucleocapsid, COVID-19 NP, COVID-19 Nucleocapsid, SARS-CoV-2 NP, SARS-CoV-2 Nucleocapsid, covid-19, sars-cov-2
Clonality: Monoclonal
Concentration: 1 mg/ml (Please refer to the vial label for the specific concentration.)
Clone Designation: [HL249]
Sensitivity: This antibody detects both SARS-CoV nucleocapsid and SARS-CoV-2 nucleocapsid proteins. Our internal testing indicates no cross-reactivity with MERS-CoV nucleocapsid protein.
Buffer: PBS, no Preservative.
Purity: Affinity purified by protein A.
Form: Liquid
Application Notes: WB: 1:5000-1:20000. ICC/IF: 1:100-1:1000. *Optimal dilutions/concentrations should be determined by the researcher.Not tested in other applications.
GTX635678 ELISA Image
Sandwich ELISA detection of recombinant full-length SARS-CoV-2 (COVID-19) nucleocapsid protein, His tag protein (GTX135592-pro) using SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL344] (GTX635679) as capture antibody at concentration of 5 μg/mL and HRP-conjugated SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] (GTX635678) as detection antibody at concentration of 1 μg/mL.
Please notice that GTX635678 needs to be conjugated to HRP to function as the detection antibody when paired with GTX635679. Please contact us for custom HRP-conjugated antibody.
Sandwich ELISA detection of recombinant full-length SARS-CoV-2 (COVID-19) nucleocapsid protein, His tag protein (GTX135592-pro) using SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL5511] (GTX635689) as capture antibody at concentration of 5 μg/mL and HRP-conjugated SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] (GTX635678) as detection antibody at concentration of 1 μg/mL.
Please notice that GTX635678 needs to be conjugated to HRP to function as the detection antibody when paired with GTX635689. Please contact us for custom HRP-conjugated antibody.
Indirect ELISA analysis performed by coating plate with recombinant full-length SARS-CoV-2 (COVID-19) nucleocapsid protein (GTX135592-pro) (50 ng). Coated protein probed with SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] (GTX635678) (2.4*10⁻⁶ ~ 20 nM). Rabbit IgG antibody (HRP) (GTX213110-01) (1:10000) detected bound primary antibody.
EC50 : 0.016 nM
Non-transfected (–) and transfected (+) 293T whole cell extracts (30 μg) were separated by 10% SDS-PAGE, and the membrane was blotted with SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] (GTX635678) diluted at 1:5000. The HRP-conjugated anti-rabbit IgG antibody (GTX213110-01) was used to detect the primary antibody.
SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] detects SARS-CoV-2 (COVID-19) nucleocapsid protein by immunofluorescent analysis.
Sample: Mock and transfected 293T cells were fixed in 4% paraformaldehyde at RT for 15 min.
Green: SARS-CoV-2 (COVID-19) nucleocapsid stained by SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] (GTX635678) diluted at 1:1000.
Blue: Fluoroshield with DAPI (GTX30920).
Indirect ELISA analysis was performed by coating plate with 50 μL of recombinant full-length SARS-CoV-2 (COVID-19) nucleocapsid protein (GTX135357-pro) and (GTX135592-pro) at concentrations ranging from 0.015 μg/mL to 1 μg/mL. The coated protein is detected with SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] (GTX635678) at 1 μg/mL. Rabbit IgG antibody (HRP) (GTX213110-01) was diluted at 1:10000 and used to detect the primary antibody.
Non-transfected (–) and transfected (+) 293T whole cell extracts (30 μg) were separated by 10% SDS-PAGE, and the membrane was blotted with SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] (GTX635678) diluted at 1:5000. The HRP-conjugated anti-rabbit IgG antibody (GTX213110-01) was used to detect the primary antibody.
Sandwich ELISA detection of recombinant full-length SARS-CoV-2 (COVID-19) nucleocapsid protein, His tag protein (GTX135592-pro) using SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL5410] (GTX635685) as capture antibody at concentration of 5 μg/mL and HRP-conjugated SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] (GTX635678) as detection antibody at concentration of 1 μg/mL.
SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] detects SARS-CoV-2 (COVID-19) nucleocapsid protein by immunohistochemical analysis.
Sample: Mock (GTX435670) and SARS-CoV-2 (COVID-19) Nucleocapsid transfected 293T cell FFPE Cell Pellet Block (GTX435641).
Green: SARS-CoV-2 (COVID-19) nucleocapsid stained by SARS-CoV-2 (COVID-19) nucleocapsid antibody [HL249] (GTX635678) diluted at 1:1000.
Blue: Fluoroshield with DAPI (GTX30920).
Antigen Retrieval: Citrate buffer, pH 6.0, 15 min