Goat F(ab)2 anti-Mouse IgG (F(ab)2)-RPE, MinX Bo,Ho,Hu, Polyclonal

Artikelnummer: DNA-SEC-183806
Artikelname: Goat F(ab)2 anti-Mouse IgG (F(ab)2)-RPE, MinX Bo,Ho,Hu, Polyclonal
Artikelnummer: DNA-SEC-183806
Hersteller Artikelnummer: SEC-183806
Alternativnummer: DNA-SEC-183806
Hersteller: dianova
Wirt: Goat
Kategorie: Antikörper
Applikation: FACS,IF,WB
Spezies Reaktivität: Mouse
Immunogen: Mouse IgG F(ab)2 fragment
Konjugation: RPE
Alternative Synonym: Goat F(ab)2 Anti-Mouse IgG F(ab)2 Antibody phycoerythrin Conjugation, Goat Fab2 Anti-Mouse IgG Fab2 PE Conjugated Antibody
Format: F(ab')2
Spezifität: IgG (F(ab')2)
Minimale Kreuzreaktivität (MinX): Bovine,Equine,Human
F(ab)2 Anti-Mouse IgG F(ab)2 Phycoerythrin Antibody generated in goat detects Mouse F(ab)2. Representing approximately 75% of serum immunoglobulins, IgG is the most abundant antibody isotype found in the circulation. IgG molecules are synthesized and sec
Klonalität: Polyclonal
Konzentration: 0.5 mg/mL
Isotyp: Ig
Puffer: 0.02 M Potassium Phosphate, 0.15 M Sodium Chloride, pH 7.2
Reinheit: F(ab')2 fragment PE conjugated Anti-Mouse IgG F(ab')2 was prepared from monospecific antiserum by immunoaffinity chromatography using Mouse IgG coupled to agarose beads followed by solid phase adsorption(s) to remove any unwanted reactivities, pepsin digestion and chromatographic separation.   Assay by immunoelectrophoresis resulted in a single precipitin arc against anti-Phycoerythrin, anti-Goat Serum, Mouse IgG, Mouse IgG F(ab’)2 and Mouse Serum.  No reaction was observed against anti-Pepsin, anti-Goat IgG F(c), Mouse IgG F(c) or Bovine, Horse or Human Serum Proteins.
Formulierung: Lyophilized
Formel: 20 mM K3PO4,150 mM NaCl,pH 7,2,lyophilisate,0,01% NaN3
Target-Kategorie: Mouse
Antibody Type: Secondary Antibody
Application Verdünnung: Flow Cytometry Dilution: 1:100 - 1:250, IF Microscopy Dilution: 1:100 - 1:250, Western Blot Dilution: 1:100 - 1:500
Anwendungsbeschreibung: Suitable for immunomicroscopy and flow cytometry or FACS analysis as well as other antibody based fluorescent assays requiring extremely low background levels, absence of F(c) mediated binding, lot-to-lot consistency, high titer and specificity. The maximum amount of reagent required to stain 1 x 10E6 cells in flow cytometry is approximately 1.0 µg of antibody conjugate.  Lesser amounts of reagent may be sufficient for staining. Optimal titers for other applications should be determined by the researcher. As a general guideline dilutions of 1:100 to 1:250 should be suitable for most applications.