Calcitonin Gene Related Peptide (CGRP) BioAssay(TM) ELISA Kit (Mouse)

Artikelnummer: USB-023850
Artikelname: Calcitonin Gene Related Peptide (CGRP) BioAssay(TM) ELISA Kit (Mouse)
Artikelnummer: USB-023850
Hersteller Artikelnummer: 023850
Alternativnummer: USB-023850-96
Hersteller: US Biological
Kategorie: Kits/Assays
Calcitonin Gene Related Peptide (CGRP) BioAssay(TM) ELISA Kit (Mouse) is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of CGRP in mouse serum, plasma, tissue homogenates, cell culture supernates and other biological fluids. Detection Range: 12.35-1000pg/ml Sensitivity: 4.36pg/ml Intra-Assay CV: <10% Inter-Assay CV: <12% Kit Components: *023850A: Microtiter Plate, 1x96 wells *023850B: Standard, 2x1 vial 023850C: Standard Diluent, 1x20ml *023850D: Detection Reagent A (green), 1x1vial *023850E: Detection Reagent B (red), 1x120ul 023850F: Assay Diluent A, 1x12ml 023850G: Assay Diluent B, 1x12ml 023850H: TMB Substrate, 1x9ml 023850H: Positive Control, 380.3pg/ml, 1x1vial 023850K: Stop Solution, 1x6ml 023850L: Wash Buffer, 30X, 1x20ml 023850M: Reagent Diluent for 023850D, 1x300ul Precaution: The Stop Solution (023850K) suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material. Notes on 023850J: Positive Control: Intended Use: The positive control is from a mouse serum sample known to contain the target protein. It will provide a positive result in the ELISA assay, which indicates that the kit is optimized and working properly. Characteristics: The positive control vial contains mouse CGRP in mouse serum (lyophilized powder). Note: The mouse based serum used in this product are from healthy mice of SPF standard (specific pathogen-free animals). Expected Values: 380.3pg/ml Usage: Dissolve with 150ul standard diluent and let stand for 10 minutes. If powder is partly insoluble, shake gently until fully dissolved. Mix gently before use. In the experiment, add 100ul to an appropriate well of the plate and test its concentration along with standards and your specimens. Note: Upon receipt store Positive Control vial at -20C. After reconstitution, store Positive Control vial at 4C and use within 5 days. Storage and Stability: Store *023850A, *023850B, *023850D, *023850E and *023850J at -20C. After reconstitution of *023850J, store at 4C and use within 5 days. Store all the other components at 4C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap. Assay Procedure Summary: 1. Prepare all reagents, samples and standards. 2. Add 50ul standard or sample to each well, then add 50ul prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37C. 3. Aspirate and wash 3 times. 4. Add 100ul prepared Detection Reagent B. Incubate 30 minutes at 37C. 5. Aspirate and wash 5 times. 6. Add 90ul Substrate Solution. Incubate 15-25 minutes at 37C. 7. Add 50ul Stop Solution. Read absorbance at 450nm immediately.