Complement Factor I (CFI) BioAssay(TM) ELISA Kit (Human)

Artikelnummer: USB-024389
Artikelname: Complement Factor I (CFI) BioAssay(TM) ELISA Kit (Human)
Artikelnummer: USB-024389
Hersteller Artikelnummer: 024389
Alternativnummer: USB-024389-48,USB-024389-96
Hersteller: US Biological
Kategorie: Kits/Assays
Complement Factor I (CFI) BioAssay(TM) ELISA Kit (Human) is a sandwich enzyme immunoassay for in vitro quantitative measurement of CFI in human serum, plasma and other biological fluids. Detection Range: 0.29-18ng/ml Sensitivity: 0.13ng/ml Intra-Assay CV: <10% Inter-Assay CV: <12% Kit Components: *024389A: Microtiter Strips, 1x96 wells *024389B: Standard, 2x1 vial 024389C: Standard Diluent, 1x20ml *024389D: Detection Reagent A, 1x120ul *024389E: Detection Reagent B, 1x120ul 024389F: Assay Diluent A, 1x12ml 024389G: Assay Diluent B, 1x12ml 024389H: TMB Substrate, 1x9ml *024389J: Positive Control, 1.76ng/ml, 1x1 vial 024389K: Stop Solution, 1x6ml 024389L: Wash Buffer, 30X, 1x20ml Precaution: The Stop Solution (024389K) suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material. Storage and Stability: Store *024389A, *024389B, *024389D, *024389E and *024389J at -20C. After reconstitution of *024389J, store at 4C and use within 5 days. Store all the other components at 4C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap. Notes on 024389J: Positive Control: Intended Use: The control vial is from a human serum sample known to contain CFI. It will provide a positive result in the ELISA assay, which indicates that the kit is optimized and working properly. Characteristics: The control vial contains human CFI in human serum (lyophilized powder). Note: The human source material used in this product is screened for HIV, Hepatits A, B, C, HTLV and Syphilis. Expected Values: 1.76ng/ml Usage: Dissolve with 150ul standard dilutent and let stand for 10 minutes. If powder is partly insoluble, shake gently until fully dissolved. Mix gently before use. In the experiment, add 100ul to an appropriate well of the plate and test its concentration along with standards and your specimens. Note: Upon receipt store Positive Control vial at -20C. After reconstitution, store Positive Control vial at 4C and use within 5 days.