Salmon Calcitonin (SCT) BioAssay(TM) ELISA Kit

Artikelnummer: USB-027952
Artikelname: Salmon Calcitonin (SCT) BioAssay(TM) ELISA Kit
Artikelnummer: USB-027952
Hersteller Artikelnummer: 027952
Alternativnummer: USB-027952-96
Hersteller: US Biological
Kategorie: Kits/Assays
The Salmon Calcitonin (SCT) BioAssay(TM) ELISA Kit is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of SCT in biological agents. Detection Range: 78.1-20,000pg/ml Sensitivity: 32.5pg/ml Intra-Assay CV: <10% Inter-Assay CV: <12% Kit Components: *027952A: Microtiter Strips, 1x96 wells, Pre-coated, ready to use *027952B: Standard, 2x1 vial 027952C: Standard Diluent, 1x20ml *027952D: Detection Reagent A (green), 1x120ul *027952E: Detection Reagent B (red), 1x120ul 027952F: Assay Diluent A, 1x12ml 027952G: Assay Diluent B, 1x12ml 027952H: TMB Substrate, 1x9ml *027952J: Positive Control, 560pg/ml, 1x1vial (Lyophilized) 027952K: Stop Solution, 1x6ml 027952L: Wash Buffer, 30X, 1x20ml Precaution: The Stop Solution (027952K) suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material. Storage and Stability: Store *027952A, *027952B, *027952D, *027952E and *027952J at -20C. After reconstitution of *027952J, store at 4C and use within 5 days. Store all the other components at 4C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap. Notes on 027952J: Positive Control: Intended Use: The positive control is from biological agents known to contain the target protein. It will provide a positive result in the ELISA assay, which indicates that the kit is optimized and working properly. Characteristics: The positive control vial contains SCT in biological agents (lyophilized powder). Expected Values: 560pg/ml Usage: Dissolve with 150ul standard diluent and let stand for 10 minutes. If powder is partly insoluble, shake gently until fully dissolved. Mix gently before use. In the experiment, add 50ul to an appropriate well of the plate and test its concentration along with standards and your specimens. Note: Upon receipt store Positive Control vial at -20C. After reconstitution, store Positive Control vial at 4C and use within 5 days. Assay Procedure Summary: 1. Prepare all reagents, samples and standards, 2. Add 50ul standard or sample to each well. 3. Add 50ul prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37C. 4. Aspirate and wash 3 times. 5. Add 100ul prepared Detection Reagent B. Incubate 30 minutes at 37C. 6. Aspirate and wash 5 times. 7. Add 90ul Substrate Solution. Incubate 10-20 minutes at 37C. 8. Add 50ul Stop Solution. Read at 450nm immediately.