| The Luteinizing Hormone (FSH) BioAssay(TM) ELISA Kit is a competitive inhibition enzyme immunoassay for in vitro quantitative measurement of LH in canine serum, plasma and other biological fluids. Detection Range: 370.4-30,000pg/ml Sensitivity: 161.3pg/ml Intra-Assay CV: <10% Inter-Assay CV: <12% Kit Components: *366283A: Microtiter Strips, 1x96 wells, Pre-coated, ready to use *366283B: Standard, 2x1 vial 366283C: Standard Diluent, 1x20ml *366283D: Detection Reagent A (green), 1x120ul *366283E: Detection Reagent B (red), 1x120ul 366283F: Assay Diluent A, 1x12ml 366283G: Assay Diluent B, 1x12ml 366283H: TMB Substcaninee, 1x9ml *366283J: Positive Control, 1x1vial, 2870pg/ml (Lyophilized) 366283K: Stop Solution, 1x6ml 366283L: Wash Buffer, 30X, 1x20ml Precaution: The Stop Solution (366283K) suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material. Storage and Stability: Store *366283A, *366283B, *366283D, *366283E and *366283J at -20C. After reconstitution of *366283J, store at 4C and use within 5 days. Store all the other components at 4C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expicanineion date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap. Notes on 366283J: Positive Control: Intended Use: The Positive Control is from is from a canine serum sample known to contain the target protein. It will provide a positive result in the ELISA assay, which indicates that the kit is optimized and working properly. Characteristics: The positive control vial contains canine LH in canine serum (lyophilized powder). Note: The canine source material used in this product are from healthy animal of SPF standard (specific pathogen-free animals). Expected Values: 2870pg/ml Usage: Dissolve with 150ul standard dilutent and let stand for 10 minutes. If powder is partly insoluble, shake gently until fully dissolved. Mix gently before use. In the experiment, add 50ul to an appropriate well of the plate and test its concentcanineion along with standards and your specimens. Note: Upon receipt store Positive Control vial at -20C. After reconstitution, store Positive Control vial at 4C and use within 5 days. Assay Procedure Summary: 1. Prepare all reagents, samples and standards. 2. Add 50ul standard or sample to each well. 3. Add 50ul prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37C. 4. Aspicaninee and wash 3 times. 5. Add 100ul prepared Detection Reagent B. Incubate 30 minutes at 37C. 6. Aspicaninee and wash 5 times. 7. Add 90ul Substcaninee Solution. Incubate 10-20 minutes at 37C. 8. Add 50ul Stop Solution. Read at 450nm immediately. |