Tetrahydrofolic Acid (THFA) BioAssay(TM) ELISA Kit (General)

Artikelnummer: USB-366599
Artikelname: Tetrahydrofolic Acid (THFA) BioAssay(TM) ELISA Kit (General)
Artikelnummer: USB-366599
Hersteller Artikelnummer: 366599
Alternativnummer: USB-366599-96
Hersteller: US Biological
Kategorie: Kits/Assays
The Tetrahydrofolic Acid (THFA) BioAssay(TM) ELISA Kit is a competitive inhibition enzyme immunoassay technique for the in vitro quantitative measurement of THFA in serum, plasma, tissue homogenates, cell lysates, cell culture supernatants and other biological fluids. Detection Range: 1.23-100ng/ml Sensitivity: 0.44ng/ml Intra-Assay CV: <10% Inter-Assay CV: <12% Kit Components: *366599A: Microtiter Plate, 1x96 wells, Pre-coated, ready to use. *366599B: Standard, 2x1vial 366599C: Standard Diluent, 1x20ml *366599D: Detection Reagent A (green), 1x1vial *366599E: Detection Reagent B (red), 1x120ul 366599F: Assay Diluent A, 1x12ml 366599G: Assay Diluent B, 1x12ml 366599H: TMB Substrate, 1x9ml *366599J: Positive Control, 10.2ng/ml, 1x1vial (Lyophilized) 366599K: Stop Solution, 1x6ml 366599L: Wash Buffer, 30X, 1x20ml 366599M: Reagent Diluent, 1x300ul Precaution: The Stop Solution (366599K) included for use in this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material. Storage and Stability: Store *366599A, *366599B, *366599D, *366599E and *366599J at -20C. After reconstitution of *366599J, store at 4C and use within 5 days. Store all the other components at 4C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap. Notes on 366599J - Positive Control: Intended Use: The control vials are from a human serum sample known to contain the target protein. It will provide a positive result in the ELISA assay, which indicates that the kit is optimized and working properly. Characteristics: The control vials contain human THFA in human serum (lyophilized powder). Note: The human based serum used in this product are screened for HIV, Hepatitis A, B, C, HTLV and Syphilis. Expected Value: 10.2ng/ml Usage: Dissolve with 150ul standard diluent and let stand for 10 minutes. Mix gently before use. In the experiment, add 50ul to an appropriate well of the plate and test its concentration along with standards and samples. Note: Upon receipt store Positive Control vial at -20C. After reconstitution, store Positive Control vial at 4C and use within 5 days. Assay Procedure Summary: 1. Prepare all reagents, samples and standards, 2. Add 50ul standard or sample to each well. 3. Add 50ul prepared Detection Reagent A immediately. Shake and mix. Incubate 1 hour at 37C. 4. Aspirate and wash 3 times. 5. Add 100ul prepared Detection Reagent B. Incubate 30 minutes at 37C. 6. Aspirate and wash 5 times. 7. Add 90ul Substrate Solution. Incubate 10-20 minutes at 37C. 8. Add 50ul Stop Solution. Read at 450nm immediately.