4-Hydroxyphenylpyruvate Dioxygenase (HPD) BioAssay(TM) ELISA Kit (Human) (Wide Range)

Artikelnummer: USB-516941
Artikelname: 4-Hydroxyphenylpyruvate Dioxygenase (HPD) BioAssay(TM) ELISA Kit (Human) (Wide Range)
Artikelnummer: USB-516941
Hersteller Artikelnummer: 516941
Alternativnummer: USB-516941-96
Hersteller: US Biological
Kategorie: Kits/Assays
Sample Type: Serum, plasma, tissue homogenates and other biological fluids Intended Use: The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of HPD in human serum, plasma, tissue homogenates and other biological fluids. Sensitivity: 1.27ng/ml Range: 3.12-200ng/ml Specificity: This assay has high sensitivity and excellent specificity for detection of Wide-range 4-Hydroxyphenylpyruvate Dioxygenase (HPD). No significant cross-reactivity or interference between Wide-range 4-Hydroxyphenylpyruvate Dioxygenase (HPD) and analogues was observed. Precision: Intra-Assay: CV<10% Inter-Assay: CV<12% Test Principle: The microplate provided in this kit has been pre-coated with an antibody specific to HPD. Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to HPD. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain HPD, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm 10nm. The concentration of HPD in the samples is then determined by comparing the O.D. of the samples to the standard curve. Kit Components: 96-well strip plate, 1x Plate Standard, 2x vial Detection Reagent A, 1*120ul Detection Reagent B, 1*120ul TMB Substrate, 1*9ml Wash Buffer (30X), 1*20ml Standard Diluent, 1*20ml Assay Diluent A, 1*12ml Assay Diluent B, 1*12ml Stop Solution, 1x6ml Storage and Stability: Store microtiter strips, Standard, Detection Reagent A, Detection Reagent B and positive control at -20C. After reconstitution of the postive control store at 4C and use within 5 days. Store all the other components at 4C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap.
UniProt: P32754