Angiotensin I Converting Enzyme 2 (ACE2, SARS Receptor) BioAssay(TM) ELISA Kit (Human)

Catalog Number: USB-023409
Article Name: Angiotensin I Converting Enzyme 2 (ACE2, SARS Receptor) BioAssay(TM) ELISA Kit (Human)
Biozol Catalog Number: USB-023409
Supplier Catalog Number: 023409
Alternative Catalog Number: USB-023409-96
Manufacturer: US Biological
Category: Kits/Assays
The Angiotensin I Converting Enzyme 2 (ACE2) BioAssay(TM) ELISA Kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of ACE2 in human serum, plasma and other biological fluids. Detection Range: 15.6-1000pg/ml Sensitivity: 5.5pg/ml Intra-Assay: CV<10% Inter-Assay: CV<12% Kit Components: *023409A: Microtiter Strips, 1x96wells, Pre-coated, ready to use *023409B: Standard, 2x1vial 023409C: Standard Diluent, 1x20ml *023409D: Detection Reagent A (green), 1x120ul *023409E: Detection Reagent B (red), 1x120ul 023409F: Assay Diluent A, 1x12ml 023409G: Assay Diluent B, 1x12ml 023409H: TMB Substrate, 1x9ml *023409J: Positive Control, 12,300pg/ml, 1x1vial (Lyophilized) 023409K: Stop Solution, 1x6ml 023409L: Wash Buffer, 30X, 1x20ml Precaution: The Stop Solution (023409K) suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material. Storage and Stability: Store *023409A, *023409B, *023409D, *023409E and *023409J at -20C. After reconstitution of *023409J, store at 4C and use within 5 days. Store all the other components at 4C. Unused kit is stable for 6 months after receipt. Once kit components are opened, it is highly recommended to use remaining reagents within 1 month provided this is within the expiration date of the kit. For maximum recovery of product, centrifuge the original vials after thawing and prior to removing the cap. Notes on 023409J: Positive Control Intended Use: The positive control is from a human serum sample known to contain the target protein. It will provide a positive result in the ELISA assay, which indicates that the kit is optimized and working properly. Characteristics: The positive control vial contains human ACE2 in human serum (lyophilized powder). Note: The human based material used in this product is screened for HIV, Hepatitis A, B, C, HTLV and Syphilis. Expected Values: 12,300pg/ml Usage: Dissolve with 150ul standard diluent and let stand for 10 minutes. If powder is partly insoluble, shake gently until fully dissolved. Mix gently before use. In the experiment, add 100ul to an appropriate well of the plate and test its concentration along with standards and your specimens. Note: Upon receipt store Positive Control vial at -20C. After reconstitution, store Positive Control vial at 4C and use within 5 days. Assay Procedure Summary: 1. Prepare all reagents, samples and standards. 2. Add 100ul standard or sample to each well. Incubate 1 hour at 37C. 3. Aspirate and add 100ul prepared Detection Reagent A. Incubate 1 hour at 37C. 4. Aspirate and wash 3 times. 5. Add 100ul prepared Detection Reagent B. Incubate 30 minutes at 37C. 6. Aspirate and wash 5 times. 7. Add 90ul TMB Substrate. Incubate 10-20 minutes at 37C. 8. Add 50ul Stop Solution. Read at 450nm immediately.